Drick help you solve common faults in tensile testing machine operation
Tensile testing machine is a new generation of tensile testing machine with novel design, easy to use,
excellent performance, elegant appearance, Transmission adopt ball screw, stable transmission and
accurate; Using imported servo motor, low noise and control precision. Large-screen LCD,
Chinese and English menu, the latest software with real-time display tensile curve function; The instrument
has powerful data display and analysis, management capabilities. In the normal course of operations,
there will be some problems for novice, common has the following kinds:
1. Prompt box information display overload after computer software online.
The solution is to check the communications line of computer and the machine whether fall off; Check
online choose sensor whether correct; Check the sensor whether knocked over when check the most
recent test or keypad; Check whether use the function of calibration or standardization of software;
Check whether manually changed calibration values, standardization values or other information of hardw
are parameters.
2. Power supply of the machine host is off and can not move up and down.
The solution is to check the power circuit of access the machine whether normal; Check the emergency
stop switch whether in a state of screwed up; Check the power voltage of access the machine whether
normal; Check the fuse of socket on the machine whether blown, please take out the spare fuse and
install it.
3. Machine power supply has power, but it can not move up and down.
The solution is to check the machine whether still can not move after 15s(time), because the machine
starting up need to self-inspection, about takes 15s time; check the upper and lower limit whether in the
right place, and has certain operating space; Check the power voltage of access the machine whether
normal.