DRK-07E Fabricae radiophonicae caloris praesidium probatorem

Brevis descriptio:

Exemplar: DRK-07E Usus ad usum radiorum caloris classis C probatio chirothecarum scelerisque velit, scelerisque velit lites et ocreas tutelares. Standard:ISO 6942 Test A+Test B、EN 366 EN 407、ISO 11611、ISO 11612 Specifications 1. Fons radialis: compositus ex sex circulis virgae calefactionis SiC, tota longitudo virgae calefactionis est 356mm±2mm; longitudo partis calefacientis est 178±2, diametri virgae calefactionis est 7.9±0.1mm; 2. Radians principium PID temperatura moderatio, temperatura.


  • MALITIA Price:US $0.5 - 9,999 / Piece
  • Min.Order Quantitas:100 Piece/Picies
  • Facultates copia:(X) Piece / Mass per mense
  • Portus:Shenzhen
  • Termini solucionis:L/C,D/A,D/P,T/T
  • Product Detail

    Product Tags

    Model:DRK-07E

     

    Use.Usus ad candidum calorem classis C probatio caestus scelerisque velit, scelerisque velit lites et ocreas tutelares.

    Standard.ISO 6942 Test A+Test B.EN 366.EN 407.ISO 11611.ISO 11612

    Specifications.

    1. Rfons adiationis: ex sex coetibus virgae calefactionis SiC, tota longitudo virgae calefactionis est 356mm .±2mm, longitudo partis calefactionis est 178 .±2, diameter virgae calefactionis est 7.9 .±0.1mm;

    2. Tille radiophonicus fons PID temperatura temperantia adoptat, temperatura moderatio praecisio est±1;

    3. Radiation fons calefaciendi facultatem: maximum 1200±5%, usura PID moderatoris;

    4. Radiation fons calor radiorum fluxus: 10 ~ 80 kW/m2;

    5. Sampling frequentia notitiarum acquisitionis card pervenire potest XX HZ;

    6. Elepide cum vicus fenestrarum mercatorum cum calore radiorum sensoris fluxi (cum fabrica circulationis aquae), maxima mensurae ambitus est 100KW/m2;

    7. Elepide cum lamina aeris calorimetri fabrica, adhibita ad deprehendendas mutationes caliditatis in dorso exempli;

    8. Copper catillus calorimeter factus est conductivity alte importato aeris purissimi sine oxygenio;

    9. Elepide cum methodo A type sample clip et methodi B type sample clip;

    10. Tille specimen movens fabrica, libere movere potest in suggestu operante;

    11. Elepide cum computatrum + JM Windows XP systema operante, parametri expositae programmatis, automatic initium test, statim metiri potest caliditatem ortum 12et 24requiritur test tempus, calor fluxus Q, calor translatio coefficientis HF;

    Magnitudine (L * W * H cm).95*66*31

    Pondus (kg).110

    Institutionem necessaria.

    1. Electrical requisita: 220V, 50HZ, 15A;

    2. Air fontem requiruntur; torcular gas

    3. Tenvironment probat: 10°C ~ 30°C

    4. Operation: portum

    5. Fumus emissio pipeline

    Configurationis.

    1. Happaratus ost;

    2. Una notam computatri;

    3. Una lamina aeris calorimetri;

    4. Una radialis sensoris pro calibratiis fluxu;

    5. Programma professionalis test ornamentum: Primus gradus ardet et secundus gradus uret curvam;

    6. Unum exemplar manuale productum;


  • Previous:
  • Next:

  • SHANDANG DRICK INSTRUMENTIS CO., LTD

    Turba Profile

    Shandong Drick Instrumenta Co., Ltd, maxime versatur in investigatione et evolutione, fabricandis et venditionibus instrumentorum probatorum.

    Societas anno 2004 constituta.

     

    Producta in investigationibus scientificis adhibentur unitates, institutiones inspectionis qualitas, universitates, fasciculatio, charta, impressio, rubber et materia plastica, oeconomiae, cibi, pharmaceutica, textilia, aliaque industria.
    Drick attendit operam ingenii culturae et quadrigae aedificationis, adhaerens evolutionis notioni professionalismi, dedicationis.pragmatismi, et innovationi.
    Principio emptori adhaerens, urgentissimas et practicas clientium necessitates solve, et primae classis solutiones clientibus cum productorum qualitate et technicis provectis praebent.

    Related Products

    Whatsapp Online Chat!