DRK357B-II Permeability Tester pro Diapers
Brevis descriptio:
Instrumentum usus: Testor permeabilitatis diapero adhibetur ad determinandam effusio velocitatem, re- permeabilitatem et permeabilitatem diapersorum et aliorum productorum. Standard: GB/T28004.1-22021、GB/T28004.2-2021 Features: Testa liquida usus in experimento sentinam peristalticam adhibet ad moderandum liquorem accessionis methodum ad stabilitatem ac repeatability liquoris additionis ac subtilitatis. liquoris additionis attingere ±1% potest. Methodus calefaciendi experimenti solutionem (salinum physiologicum) adop...
Instrumentum usus.
Testor permeabilitatis diapero adhibetur ad determinare effusio velocitatem, re- permeabilitatem et permeabilitatem diapersorum et aliorum productorum.
Standard.
GB/T28004.1-22021、GB/T28004.2-2021
Features.
Experimentum liquidum, quo usus in test, sentinam peristalticam adhibet, ut liquorem adiectionis modum moderetur ut firmitatem et iterabilem liquoris additionis ac subtilitatem liquoris additionis ±1% attingere possit.
Methodus calefactio solutionis experimenti (salinae physiologicae) methodum calefactionis balnei accipit et in olla vitrea reponitur sine ulla influentia in solutione experimenti faciendi.
Testi specimen adfixa pro foenore liberorum: 3 basibus U informibus, 3 detentoribus specimen, 3 moduli liquidi moduli additi, et 3 modulorum pressuris signatorum.
Adultus diaperi specimen tenens: 1 basis informata U, 2 modulus liquor moduli addens, et 2 moduli moduli pressus premens.
Omnia fixtures specimen fiunt ex materia PA66 ex impressione 3D, cum valida repugnantia, corrosio resistentia et resistentia calidissima.
Tota machina fabrica escritorio consilium capit, quod stabilis est in operatione et commodius ad movendum et instituendum.
Systema transmissionis servo motore et pilae cochleae adhibet, quae aequaliter currit et accurate moderatur.
Instructus cum duobus-dimensionalibus codice functionibus perspiciendis, automatice codicibus exempla colligendis, et notitiarum experimentorum fluxus intelligens et efficax est.
Automatarie functiones testium completas ut liquidum et pressorium addens, et parametros automatice memorant ut celeritas effusio.
Statera importata instructus, ratio automatice pondus legit et relationes testium producit.
Instructus a Micro scelerisque typographus ad facilem impressionem testium data.
Instructus programmate interretiali, data test, exportare aliaque munera in PC inspicere potes.
Voce prudenti instructus munus promptum est admonere utentes ad actionem testium proximam ingrediendam.
Praecipuum imperium a STMicroelectronics 32 frenum MCU adoptat, qui cum Rerum Interreti munere instrui potest ad faciliorem datam accessum ad systema ERP emptoris.
Adhibet tactus screen imperium et ostentationem, Sinica et Anglica operandi genus interface menu.
Technical parametri.
1. Test parametri magnitudinem natorum diapers
1.1 Parametri U informibus exempli basi;
B1: L: 125±1mm W: 122±1mm
B2: L: 136±1mm W: 135±1mm
B3: L: 154±1mm W: 152±1mm
1.2. Parametri vexillum dosing moduli:
M1: L: 100±1mm W: 80±1mm
M2: L: 108±1mm W: 85±1mm
M3: L: 125±1mm W: 95±1mm
1.3. Latin modulus test pressura:
Y1: L: 100±1mm W: 80±1mm
Y2: L: 108±1mm W: 85±1mm
Y3: L: 125±1mm W: 95±1mm
Adulta diaper test parametri magnitudine
2.1, U-formatus basi parametri;
L: 319±1mm W: 200±1mm
2.2. Parametri vexillum dosing moduli:
M1: L: 170±1mm W: 70±1mm
M2: L: 170±1mm W: 95±1mm
2.3. Latin modulus test pressura:
Y1: L: 170±1mm W: 70±1mm
Y2: L: 170±1mm W: 95±1mm
Liquidum volumen:
3.1. Infantem diapers:
3.1.1. Small (S) code and below: (40±2)ml
3.1.2. Medium (M) size: (60±2)ml
3.1.3 Magnae magnitudinis (L) et supra: (80±2) ml
3.2. Infantem diapers:
3.2.1. Small (S) code and below: (30±2)ml
3.2.2. Medium (M) size: (40±2)ml
3.2.3 Magnae magnitudinis (L) et supra: (50±2)ml
3.3. Adulta diapers:
3.3.1: Products cum moderata incontinentia: (100±2)ml
3.3.2: Gravis incontinentia producta: (CL±2)ml
3.4. Adulta diapers:
3.4.1: Incontinentia moderata producta: (70±2)ml
3.4.2: Gravis incontinentia producta: (100±2)ml
4. Pressura pressio: 2.0±0.2 KPa, 4.0±0.2 KPa
5. Addens liquidum rate fluens: 480±10ml/min (pueri), 720±10ml/min (adultis)
6. Timing range: 0.00 ~ 9999.99 s
7. Calefaciens range ex test solutione: locus temperatus +5℃~50℃
8. Potentiae copia: AC220V, 200W, 50Hz
9. Magnitudo L×W×H: 320mm×220mm×500mm
Configurationis album.
1. 1 exercitum
2. I aqua balneum
3. Infans diaper test fixture 1 set (U-formata basi B1, B2, B3, specimen possessor T1, T2, T3, vexillum test liquidum addens moduli M1, M2, M3, vexillum test pressionis moduli Y1, Y2, Y3)
4. Adulta diaper test fixture 1 set (basi U informibus B, vexillum test liquidum addens moduli M1, M2, vexillum test moduli pressurizing Y1, Y2)
5. I turba BIBULUS chartam
6. Importari statera I set
7. I productum certificatorium
8. Product manual 1 exemplum
9. 1 partus note
10. I acceptatio sheet
11. Product album 1 copy
Libitum album
Upgrade munus nexu IoT
SHANDANG DRICK INSTRUMENTIS CO., LTD
Turba Profile
Shandong Drick Instrumenta Co., Ltd, maxime versatur in investigatione et evolutione, fabricandis et venditionibus instrumentorum probatorum.
Societas anno 2004 constituta.
Producta in investigationibus scientificis adhibentur unitates, institutiones inspectionis qualitas, universitates, fasciculatio, charta, impressio, rubber et materia plastica, oeconomiae, cibi, pharmaceutica, textilia, aliaque industria.
Drick attendit operam ingenii culturae et quadrigae aedificationis, adhaerens evolutionis notioni professionalismi, dedicationis.pragmatismi, et innovationi.
Principio emptori adhaerens, urgentissimas et practicas clientium necessitates solve, et primae classis solutiones clientibus cum productorum qualitate et technicis provectis praebent.