Productum introductio DRK-1000 Bacterial Efficientia Filtrationis Detector non solum congruens cum exigentiis larvarum technologiarum medicorum chirurgicarum YY0469-2011 appendix B in methodo probati ad efficientiam colum (BFE) bacteria prima b. 1.1.1 instrumenti examinis, sed etiam conformis societati Americanae ad probandam materiam ASTMF2100, ASTMF2101, requisita signa Europae EN14683, incrementa aucta sub hoc fundata sunt, cum duplici antithesi pneumatica methodo sampling ...


  • MALITIA Price:US $0.5 - 9,999 / Piece
  • Min.Order Quantitas:100 Piece/Picies
  • Facultates copia:(X) Piece / Mass per mense
  • Portus:Shenzhen
  • Termini solucionis:L/C,D/A,D/P,T/T
  • Product Detail

    Product Tags

    Product introduction

    DRK-1000 Filtration Bacterial Efficens Detector non solum congruens cum exigentiis larvarum technologiarum medicorum chirurgicarum YY0469-2011 appendix B in methodo probati ad efficientiam colum (BFE) bacteria prima b. 1.1.1 instrumenti examinis, sed etiam conformis societati Americanae ad probandam materiam ASTMF2100, ASTMF2101, requisita signa Europae EN14683, incrementa aucta sub hoc fundata sunt, cum duplici antithesi pneumatica methodo simul sampling, emendare. praecisio sampling, Apta est ad metiendas et probandas Dicasteriorum, Institutorum investigationis scientificae, artifices larvarum et alias pertinentes rei ad probandum efficientiam filtrationis effectionis larvae bacteriales.

    Supplicium vexillum

    YY0469

    Q/0212 ZRB003-2015

    ISO/DIS 22611

    ASTMF2101

    EN14683

    Product features

    1.Negative pressionis ratio examinis ad salutem operariorum curare;

    2.Built - in sentinam peristalticam in pressione negativa scrinium, A, B duo - modo sex Andersen; sentinam peristalticam fluere potest;

    3. Fluxus rate noctis imbre exponi potest et effectus atomization bonus est.

    4.Embedded summus celeritas microcomputer industrialis imperium; 10.4 pollices industriae summus splendor color tactus screen;

    5.USB interface, U orbis notitia repono;

    6. Cabinet aedificavit in summo splendore luminaria;instructum in lacus tutelam transitum ad salutem operantium tuendam;

    7. Interna tabulae scrinii ex ferro immaculato factae, stratum externum cum plastic et frigido-voluto spargitur, et strata interiora et exteriora insulantur et flamma retardant.

    8. Ante switch type vitreae ianuae opportunus est experimento ad observandum et operandum.

    9.Detachable bracket, adjustable bracket altitudinis, supportantes et movens duo propositi probi.

    Formularium:

    Key Specification

     

    Specificatio dolor

    Resolution

    Sagacitas

     

    A Route Sampling flow

    28.3L/min

    0.1L/min

    Intra ± 2.5%

    B Route Sampling flow

    28.3L/min

    0.1L/min

    Intra ± 2.5%

    Imbre flow

    (8~10) L/min

    0.1L/min

    Intra ± 2.5%

    Peristalticum Pump flow

    (0.006~3.0) mL/min

    0.001ml/min

    Intra ± 2.5%

    Ante Pressio itineris

    Sampling Flowmeter

    (-20~0) kPa

    0.01kPa

    Intra ± 2.5%

    Ante Pressura B itineris

    Sampling Flowmete

    (-20~0) kPa

    0.01kPa

    Intra ± 2.5%

    Ante Pressio de

    Flometer imbre

    (0~300) kPa

    0.01kPa

    Intra ± 2.5%

    Ambiens Temperature

    (-40~99)

    0.1℃

    Intra ± 2.5%

    Negative Pressura Aerosol

    Cubiculum

    (-90~-120) Pa

    0.1Pa

    Intra ± 2.0%

    Negans Pressura scrinium

    -50~-200pa

     

    Data Repono Facultates

    > 10000 sets

     

    Vortex Mixer Test Tube

    Specification et quantitate

    Φ16×150mm test tube,8pcs

    Princeps Efficens Particulate Air

    Filtrum Properties

    Filtra Efficiency≥99.99% pro particulis> 0.3μm

    Medus diam vitae massa aerosol generans

    Diameter mediocris: (3.0±0.3)µm; Geometrica Standard

    generator massa Deviation≤1.5

     

    Duplex Itineribus VI-vecti Andersen Sampling apparatus

    Level1>7μm; Level 2: (4.7~7)μm;

    Level 3: (3.3~4.7)μm; Level 4: (2.1~3.3)μm;

    Level 5: (1.1~2.1) μm; Level 6: (0.6~1.1) μm

    Magnitudinem Aerosol Cubiculum

     

    600×85×3mm (Length×Diameter×Thickness)

     

    Totalis numerus positivum qualitas

    imperium sampler particularum

    (2200±500)cfu

     

    Negans Cubiculum fluunt celeritatis

    ≥5m3/min

     

    Magnitudinem Negative Pressura

    Chamber Door (W×D)

    1000×730mm

    Magnitudinem Main Machina (W×D×H)

    1180×650×1300mm

     

    Magnitudinem Supporting

    Artus(W×D×H)

    1180×650×600mm, altitudo intra 10cm aptabilis est

    Vox Tester

    <65dB(A)

     

    Pondus

    150kg

     

    Potestas Supple

    AC220V±10%, 50Hz

     

    Virtus Consummatio

    <150W

     


  • Previous:
  • Next:

  • SHANDANG DRICK INSTRUMENTIS CO., LTD

    Turba Profile

    Shandong Drick Instrumenta Co., Ltd, maxime versatur in investigatione et evolutione, fabricandis et venditionibus instrumentorum probatorum.

    Societas anno 2004 constituta.

     

    Producta in investigationibus scientificis adhibentur unitates, institutiones inspectionis qualitas, universitates, fasciculatio, charta, impressio, rubber et materia plastica, oeconomiae, cibi, pharmaceutica, textilia, aliaque industria.
    Drick attendit operam ingenii culturae et quadrigae aedificationis, adhaerens evolutionis notioni professionalismi, dedicationis.pragmatismi, et innovationi.
    Principio emptori adhaerens, urgentissimas et practicas clientium necessitates solve, et primae classis solutiones clientibus cum productorum qualitate et technicis provectis praebent.

    Related Products

    Whatsapp Online Chat!